Product Overview

A compact LiFePO4 battery (12V class, 12.8V nominal, 7Ah, about 90Wh) for the standard 12V 7Ah sealed lead-acid replacement market — one of the highest-volume 12V battery formats, used in alarm panels, access control, small UPS units, ride-on toys, sprayers, fish finders and medical carts.

For distributors, security integrators and private-label brands, it is a classic repeat-purchase SKU. LJY Energy supports cell configuration, BMS settings, terminals and branding to match the devices your customers use.

WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)

Specifications

Status key: [Industry reference] = the base definition of this model class or an arithmetic value, not an LJY test result. [Optional configuration] = available by OEM/ODM project. [Confirmed per project] = fixed only in the datasheet issued with your quotation (cell option, BMS rating, dimensions, weight, terminals, documents). We do not publish unverified values — request the datasheet.

Group Parameter Value Status
Cell & chemistry Battery chemistry LiFePO4 (lithium iron phosphate) [Industry reference]
Electrical Nominal voltage 12V class — 12.8V (4S) [Industry reference]
Electrical Rated capacity 7Ah [Industry reference]
Electrical Energy approx. 90Wh [Industry reference]
Electrical Charge voltage (bulk/absorption) 14.2–14.6V (no float required) [Industry reference]
Electrical Discharge cut-off voltage Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Electrical Continuous discharge current Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Electrical Peak discharge current Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Cell & chemistry Cell type Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Mechanical Dimensions (L×W×H) Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Mechanical Weight Confirmed per project (datasheet issued with quotation) [Confirmed per project]
Mechanical Terminals Confirmed per project (datasheet issued with quotation) [Confirmed per project]
BMS & protection Built-in BMS Over-charge / over-discharge / over-current / short-circuit / temperature protection, balancing [Industry reference]
Optional configuration Bluetooth app monitoring Cell voltages, SOC, temperature [Optional configuration]
Optional configuration Low-temperature protection / self-heating Charge cut-off below 0°C; heating version [Optional configuration]
Optional configuration Higher-current BMS See BMS selection guide below [Optional configuration]
Optional configuration Enclosure / branding Custom case color, logo, labels, packaging [Optional configuration]
Optional configuration Series / parallel expansion Max series/parallel count confirmed per BMS [Optional configuration]
Optional configuration 9Ah / 10Ah variants in the same case Higher capacity in identical footprint [Optional configuration]
Optional configuration Lead wire / connector For OEM devices instead of spade terminals [Optional configuration]
Commercial & documents Certifications / test documents Per order and target market [Confirmed per project]
Commercial & documents Warranty terms Per order agreement [Confirmed per project]
Commercial & documents Lead time Per order quantity and configuration [Confirmed per project]
Commercial & documents Pricing Quoted per inquiry [Confirmed per project]

BMS, Communication & Protection

Every pack uses a built-in battery management system with over-charge, over-discharge, over-current, short-circuit and temperature protection plus cell balancing. The BMS current rating sets what the battery can actually deliver, so it should be chosen from the load — not from the capacity. The guide below is general engineering guidance; the BMS rating offered for your order is confirmed in the quotation.

BMS sizing guide

Load / use case Suggested BMS rating
Alarm panels, access control, standby (under ~2A) 7A BMS
Small UPS, toys, sprayers (up to ~7A, short surges) 10A BMS
Higher continuous load Use 12V 20Ah or larger

Ask for the cell configuration on any 7Ah quote: a 32700 4S1P pack is often closer to 6Ah, while 26650 4S2P builds give more real capacity. We state the configuration in the datasheet. Charging: use a LiFePO4 profile (14.2–14.6V absorption, equalization off). See the charging voltage chart.

Size & Fitment

The common 12V 7Ah SLA case is approx. 151 × 65 × 94 mm (industry reference for the lead-acid format). Send the device compartment size and terminal width (F1 or F2) and we specify the enclosure to match. Final dimensions, weight and terminal layout are confirmed per project in the datasheet issued with your quotation.

Check that the device does not hold a lead-acid float voltage for long periods; LiFePO4 prefers a lithium charge profile.

Applications

  • Alarm panels, fire and security systems, access control
  • Small UPS and network backup
  • Kids ride-on toys and electric scooters (small)
  • Agricultural backpack sprayers
  • Fish finders and portable electronics
  • Emergency and solar garden lighting

Application limits

  • Not for engine starting.
  • Some UPS chargers float at lead-acid voltages continuously — confirm compatibility before mass replacement.
  • Standard version should not be charged below 0°C without low-temperature protection.

See also: Marine Battery Solutions · Telecom Backup Power Solutions · Product catalog.

OEM / ODM Options

  • Branding: case color, logo printing, labels, user manual and retail packaging.
  • Electrical: capacity variant, BMS continuous/peak current, charge limits.
  • Monitoring & communication: Bluetooth app, SOC display, RS485 / CAN where the system needs it.
  • Environment: low-temperature charge protection or self-heating.
  • Mechanical: enclosure size, terminals, handles, mounting and connector type.

How we help new battery brands configure this model

  • 1. Define the use case: application, largest load / inverter or controller, charging sources and climate.
  • 2. Pick the configuration: we map that to cell option, BMS rating, monitoring and enclosure, and flag trade-offs.
  • 3. Sample stage: evaluate samples against your own tests and documentation needs.
  • 4. Pilot order: confirm labeling, packaging and document package.
  • 5. Repeat supply: lock the specification so reorders stay consistent.

Wholesale & Supply Chain

LJY Energy is a China-based LiFePO4 battery supplier and OEM/ODM solutions provider offering customization, project-confirmed specifications and export supply coordination. We support configuration, project-confirmed inspection and documentation arrangements, and export logistics for importers, distributors, brands and installers. Lithium batteries ship as dangerous goods (UN3480, Class 9); the document package for your order is confirmed per inquiry. See the product catalog, our sample order guide and the wholesale & distributor program.

What to include in your inquiry

  • Device type/model and charger specification
  • Terminal type (F1/F2) and orientation
  • Load current and standby time needed
  • Target market (for documents/labels), estimated quantity and branding needs

WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)

OEM / Private-Label Options

For private-label brands and distributors, this 12.8V (12V class) model can be adapted to your market. Appearance, color and logo customizable per customer request; electrical options are confirmed in the project specification.

Option What can be configured Status
Appearance & colour Case colour, finish, front panel layout Configurable per project
Logo, labels & packaging Your logo, rating labels, carton print, manuals, retail box Configurable per project
Enclosure / size fit Small SLA-replacement formats (e.g. common 7–12Ah AGM case sizes) To be confirmed per project
BMS communication (optional) Bluetooth app, RS485 or CAN where the application needs it Optional configuration — confirmed per project
Self-heating Low-temperature charge heating for cold climates Available on request, to be confirmed per project
Terminals M6/M8 stud or other terminal type for the application To be confirmed per project

RFQ fields — send these with your inquiry

  • Application (RV, marine, solar, mobility, backup, etc.)
  • Voltage / Ah required (and series/parallel plan)
  • Inverter or charger model and firmware version
  • Climate (lowest charge temperature, highest ambient)
  • Estimated annual volume
  • Logo / appearance / packaging needs
  • Target market (for documentation scope)

Send your RFQ for LJY-12V7-STD · WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)

Other capacities in this 12V series

Same OEM/ODM platform, different capacity: 9Ah · 12Ah · 20Ah · 50Ah · 100Ah · 135Ah · 150Ah · 200Ah · 230Ah · 300Ah · 400Ah · 460Ah · 200Ah self-heating. Full ladder with energy values and scenarios: 12V 150Ah series section.

Compare with neighbouring capacities

12V-class models on this site next to this one. Nominal energy is nominal voltage × rated capacity (12.8V × Ah): an arithmetic reference, not a measured value. Usable energy depends on depth of discharge, BMS settings and temperature. Reference values reviewed 2026-10-15; final values are confirmed in the datasheet issued with your quotation.

Model Nominal energy (V × Ah) Energy vs this model Typical use class (industry reference)
12V 7Ah (this page) 89.6Wh (12.8V × 7Ah) This model Alarm, UPS, small SLA replacement
12V 9Ah 115.2Wh (12.8V × 9Ah) +26Wh (+29%) Alarm, UPS, small SLA replacement
12V 12Ah 153.6Wh (12.8V × 12Ah) +64Wh (+71%) Small SLA replacement, signs, tools

Related Products

Frequently Asked Questions

Can it replace a lead-acid battery directly?

Usually, after checking charger profile, terminal type/orientation and compartment dimensions. Some devices also have a low-voltage cut-off tuned for lead-acid. See our LiFePO4 vs lead-acid guide.

Are the specifications on this page fixed?

No. The exact cell option, BMS rating, dimensions and documents are confirmed in the datasheet issued with your quotation.

Can you supply it under my own brand?

Yes — case color, logo, labels, manual and packaging are standard OEM options; electrical and monitoring changes are handled as ODM configuration.

Is a 12V 7Ah LiFePO4 the same size as a 7Ah SLA?

It is specified to replace the standard 12V 7Ah SLA case. Final dimensions and terminal type (F1/F2) are confirmed per project in the quotation datasheet — always check them against the device.

Will it work in my alarm panel or UPS?

In many cases yes, but alarm and UPS chargers are designed for lead-acid float charging. Tell us the panel/UPS model so we can confirm charger compatibility before a volume order.

How is MOQ set?

MOQ is confirmed per project stage — sample, pilot and production — and depends on cells, tooling and branding scope. Logo-only changes usually differ from new-tooling projects.

Which certificates apply to this model?

Certificate scope is confirmed per model and per order (e.g. shipping documents such as UN38.3 / MSDS). Custom changes can affect scope, so we confirm it before quotation.

Can I get cell traceability documents?

Cell traceability documents (cell brand/model, batch information, codes where available) are provided on request and confirmed per project.

Is self-heating standard?

No. Self-heating is available on request and is to be confirmed per project.

Values marked [Confirmed per project] are fixed in the order specification. Product images are illustrative renders, not photographs of production units. Content as of October 2026.