Outdoor IP65 Wall-Mounted LiFePO4 Battery (51.2V, 100Ah / 200Ah)

Product Overview
A 51.2V (48V class) wall-mounted LiFePO4 battery in an outdoor-oriented, IP65-class enclosure option, offered at 100Ah (≈5.12kWh) and 200Ah (≈10.24kWh). It is for installers who need to mount storage on a carport, façade, balcony or plant-room exterior instead of indoors.
Our existing wall-mounted pages (51.2V 100Ah, 51.2V 200Ah) cover the indoor format. This page covers the outdoor enclosure format, which distributors in Australia, the GCC and Africa re-order for sites where indoor space is not available. For import requirements in those markets, see the Saudi Arabia and UAE import checklist and the Africa import guide for Nigeria, Kenya, South Africa and Ghana. The IP rating of your build is confirmed per project.
Appearance, color and logo customizable per customer request.
WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)
Specifications
How to read Status — three classes: [Industry reference] = standard reference parameter common to this product class (not an LJY test result). [Optional configuration] = configurable per OEM/ODM project (BMS communication, parallel/series setup, heating, enclosure, logo). [Confirmed per project] = fixed only in the datasheet issued with your quotation. Arithmetic: energy = nominal voltage × Ah.
| Group | Parameter | Value | Status |
|---|---|---|---|
| Electrical | Voltage class | 51.2V (48V class), 16S | [Industry reference] |
| Electrical | Capacity / energy | 100Ah ≈ 5.12kWh · 200Ah ≈ 10.24kWh | [Industry reference] — arithmetic |
| Verification | Capacity confirmation method | Stated Ah and Wh are confirmed per project by the method agreed in the quotation (examples used in this industry: constant-current discharge to the BMS cut-off, BMS-reported capacity after a controlled cycle, or a factory capacity/test summary supplied with the shipment). This page does not publish a measured capacity figure. | [Confirmed per project] |
| Electrical | Charge / discharge current | Common market class ~100A (100Ah) to ~100–200A (200Ah) | [Industry reference] · [Confirmed per project] |
| Electrical | Operating voltage window | 16S LiFePO4 window; exact cut-offs in datasheet | [Confirmed per project] |
| Enclosure | Ingress protection | IP65-class outdoor enclosure option | [Optional configuration] · rating [Confirmed per project] |
| Enclosure | Sealing, cable glands, breaker cover | Per enclosure design | [Confirmed per project] |
| Enclosure | Colour / logo / labels / packaging | Customer-specified | [Optional configuration] |
| BMS | Protections | Over-charge/discharge, over-current, short-circuit, temperature | [Industry reference] |
| BMS | Communication | CAN / RS485 to inverter; protocol per project | [Optional configuration] |
| BMS | Parallel units | Configured per project; no fixed maximum published | [Optional configuration] |
| Thermal | Self-heating | Available on request | [Optional configuration] |
| Thermal | High-temperature derating / thresholds | Configurable BMS thresholds; derating per project | [Confirmed per project] |
| Mechanical | Dimensions / weight / bracket | Per enclosure design | [Confirmed per project] |
| Cells | Cell brand / traceability documents | Stated per order; documents on request | [Confirmed per project] |
| Commercial | Certificates / MOQ / lead time / warranty | Per model and order | [Confirmed per project] |
Optional configurations (OEM/ODM)
LJY Energy supplies this model as an OEM/ODM configurable build. The items below are configured per customer project — they are not fixed catalog defaults.
- Enclosure: IP65-class outdoor housing — rating confirmed per project.
- BMS communication: CAN/RS485, protocol set to your inverter.
- Parallel units: configured per project.
- Self-heating: available on request, to be confirmed per project.
- Branding: Appearance, color and logo customizable per customer request.
BMS, communication & protection
Outdoor units see wider temperature swings. BMS temperature thresholds and current limits should be set for the site climate.
BMS sizing guide
| Load / use case | Suggested BMS rating |
|---|---|
| Hot, sunny site (GCC, AU, Africa) | Shade + configured high-temperature limits |
| Cold site | Self-heating option (to be confirmed) |
| Multiple units | Parallel setup confirmed per project |
IP65 protects against dust and water jets; it does not make direct sun exposure safe. No verified high-temperature performance is claimed.
Size, handling & fitment
Mount on a load-bearing wall; check bracket and anchor rating for the unit weight (confirmed per design).
Install in shade with airflow clearance; avoid direct sun and enclosed hot spaces.
Use the specified cable glands and keep covers closed to maintain the enclosure rating.
Spec, compliance & configuration fields
Use this table to prepare an RFQ for the outdoor IP65-class wall unit (100Ah / 200Ah).
| Group | Parameter | Value | Status |
|---|---|---|---|
| Energy | Nominal energy | 51.2V × 100Ah = 5,120.0Wh (5.12kWh) | [Industry reference] — arithmetic |
| Energy | Usable energy at an example DoD | At 90% DoD ≈ 4.61kWh; at 80% DoD ≈ 4.10kWh. Example only: the real DoD limit is set by BMS and inverter settings | [Industry reference] · [Confirmed per project] |
| Energy | 200Ah option | 51.2V × 200Ah = 10,240Wh (10.24kWh); 90% DoD ≈ 9.22kWh; 80% DoD ≈ 8.19kWh (example) | [Industry reference] |
| Enclosure | IP rating options | IP20 / IP21 (indoor) or IP65-class (outdoor enclosure) offered as options by project; rating and test basis confirmed per order. Some import markets use enclosure IP class in customs or tender classification — check with your broker | [Optional configuration] · [Confirmed per project] |
| Thermal | Operating temperature and heat derating | Charge / discharge temperature windows and the derating curve are set in the BMS and confirmed per project (see the climate guidance on this page where present) | [Confirmed per project] |
| Life | Cycle life — test-condition fields | Quote cycle life only with: DoD, charge / discharge C-rate, ambient temperature, end-of-life capacity %, cell type. Values are confirmed per project; no figure is claimed here | [Confirmed per project] |
| Commercial | Warranty structure | Structure to confirm per order: years vs cycles vs energy throughput, conditions (DoD, temperature, installation), who handles service | [Confirmed per project] |
| Documents | Certificate / test-report documents | Provided per order if available — confirm at inquiry. This page does not state that LJY holds any certificate or report | [Confirmed per project] |
| Documents | Importer-held certificates (OEM note) | Where an importer or brand owner holds or obtains certificates in its own name, scope, labeling and supporting documents are agreed in the OEM/ODM project | [Optional configuration] · [Confirmed per project] |
| Communication | Ports | CAN and RS485 as typical BMS ports; dry-contact or other ports on request | [Optional configuration] |
| Communication | Protocol profiles | Optional profiles for inverter families such as Deye, Growatt, Luxpower, Victron-type, Pylontech-style: to be confirmed per project against the exact inverter model and firmware. This is not a compatibility claim and no compatibility list is published | [Optional configuration] · [Confirmed per project] |
| Supply options | Supply scope (pack, enclosure, components) | Complete finished wall-mounted outdoor-format batteries; enclosures and components (cells, BMS, modules, harness) for customers who assemble locally; and OEM/ODM pack programs, coordinated per project. The quotation separates existing standard configuration, customizable options and items still to be confirmed. Cell-level supply: see LiFePO4 prismatic cells wholesale | [Optional configuration] · [Confirmed per project] |
| Branding | Private label | Logo, colour, labels and packaging; Appearance, color and logo customizable per customer request | [Optional configuration] |
| Logistics | Weight and shipping data | Net / gross weight, carton or crate size and pallet data are confirmed per model before quoting | [Confirmed per project] |
Rows labelled [Industry reference] are arithmetic or market norms, not LJY measurements. [Optional configuration] items are available by project; [Confirmed per project] items are stated per order. Send your target market, inverter model and documents needed with your inquiry.
Applications
- Carport and façade home storage
- Off-grid homes and farms
- Small shops and telecom-adjacent sites
- Installer standard outdoor SKU
Application limits
- IP rating is per enclosure design and confirmed per project.
- Not for submersion.
- Do not install in direct sun without shading.
See also: Home Energy Storage Solutions · Off-Grid Energy Storage · Product catalog.
OEM / ODM & wholesale
LJY Energy is a China-based LiFePO4 battery supplier and OEM/ODM solutions provider offering customization, project-confirmed specifications and export supply coordination. Appearance, color and logo customizable per customer request. Certificate and documentation scope (e.g. UN38.3 / MSDS for shipping) is confirmed per model, order and target market — request the current document package. See the product catalog and wholesale & distributor program.
What to include in your inquiry
- Application and site (home, C&I, off-grid, backup)
- Voltage / Ah / kWh target
- Mounting location (carport, façade, balcony) and sun exposure
- Inverter or PCS model and firmware
- Climate (min/max ambient, indoor/outdoor)
- Annual volume
- Logo / appearance / packaging needs
- Target market (documentation scope)
WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)
Related products & guides
- 51.2V 100Ah Wall-Mounted (indoor)
- 51.2V 200Ah Wall-Mounted (indoor)
- 51.2V 280Ah Wall-Mounted
- 51.2V 314Ah Floor Cabinet (hot-climate notes)
- Product catalog
- Closed-loop inverter communication guide for 51.2V batteries
- Installer path for low-voltage 51.2V (48V class) storage: what to confirm before ordering and how to send an installer inquiry. A high-voltage stack is a separate series with its own page.
RFQ fields — send these with your inquiry
- Inverter brand/model and firmware version
- Required Ah (100Ah / 200Ah class) and wall load limit
- Outdoor mounting location (sun / dust / salt air)
- Lowest charge temperature and highest ambient
- Estimated annual volume
- Logo / appearance / packaging needs
- Target market (documentation scope)
Send your RFQ for LJY-51V-WALL-IP65 · WhatsApp: +1 404 784 1946 (backup: +86 159 8945 0735)
Frequently Asked Questions
Can it be installed in full sun?
No. Install in shade with airflow; IP65 is about dust and water, not heat.
Is IP65 guaranteed?
The IP rating is an enclosure option and is confirmed per project and design.
How is MOQ set?
MOQ is confirmed per project stage (sample, pilot, production) and depends on cells, enclosure tooling and branding scope.
Which certificates apply?
Certificate scope is confirmed per model, order and target market. We do not claim certifications on this page.
Is it compatible with my inverter?
We do not publish a compatibility list. Communication protocol and settings are confirmed against your exact inverter or PCS model and firmware per project.
Values marked [To confirm] or [Competitor public] are not LJY-verified defaults. Product images are product renders for illustration. Content as of October 2026.

