On the ECG network in Accra and other Ghanaian cities, outages and a standby diesel set are part of how many shops, offices and compounds already work — and the fuel bill shows it. Dealers and installers look for a LiFePO4 backup battery in Ghana matched to the inverter already on site, so the bank covers typical cut hours and the generator starts less often. That is not the same brief as a Nigeria inverter-sizing guide, nor the four-country import checklist that already covers Ghana at the document level.
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory. We supply 12.8 V, 25.6 V and 51.2 V modules and confirm the charge window with the inverter in writing. Design, installation and clearance at Tema stay with your team and your broker.

Send inverter voltage, outage hours and Tema as the port · WhatsApp +86 159 8945 0735
Modules for ECG outages
| Module | Nominal energy | When it fits |
|---|---|---|
| 12.8 V 200 Ah | 2.56 kWh | a 12 V inverter in a small shop or home |
| 25.6 V 200 Ah | 5.12 kWh | 24 V systems |
| 51.2 V 100 / 200 Ah wall-mount | 5.12 / 10.24 kWh | a 48 V hybrid inverter; outdoor rating confirmed per project |
| 51.2 V 200 Ah rack | 10.24 kWh per module | longer autonomy or several loads; paralleled count confirmed per project |
Example: 4 kWh used during typical outage hours ÷ 0.8 = 5 kWh nominal, for instance one 5.12 kWh module. This is reference arithmetic; sizing and inverter pairing are confirmed per project. LJY does not claim a Ghanaian product mark.
What the dealer or installer should close
- Voltage of the inverter already on site, and the hours of ECG outage you actually plan to cover — not the monthly average load.
- Whether the diesel set stays as backup on the longest cuts; the bank does not have to cover every hour of the month.
- DC current of the bank versus pumps and air-conditioning start-up.
- Arrival at Tema: a UN38.3 summary and SDS come with the quotation; clearance stays with the importer. A local mark, if it is required, is confirmed per order.
- In Accra and Tema an internal heater is usually unnecessary.
For dealers who repeat the same layout
The same module set, repeated at several shops or compounds, simplifies stock and commissioning. After the first site is confirmed, later orders repeat the layout. Figures for price and timing are reserved for the formal quote.

How we proceed
Inverter voltage, outage hours, target autonomy and Tema → quotation → first site → later orders. Prices and lead times only in the quotation.
Request a backup quotation for Ghana
LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.