The MultiPlus-II 48/3000/35-32, 48/5000/70-50, 48/8000/110-100, 48/10000/140-100 and 48/15000/200-100 units form one 48 V inverter/charger family. Anyone searching for a Victron MultiPlus-II 48V battery checklist needs the official battery-voltage window, the current limit by model and the ports, not a compatibility verdict inferred from a 51.2V name or copied from another family. The official range is 38–66 V; 66 V is confirmed per project. Unlike hybrids with a direct CAN or RS485 battery port, this family is integrated through VE.Bus and a GX device, and the 57.6 / 55.2 / 52.8 V figures in the datasheet are factory defaults, not a LiFePO4 setting.
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory and we do not sell this inverter. We coordinate 51.2V modules with CAN or RS485 when a project asks for that port. The charge settings, the charge window and the intended port are confirmed per inverter model and firmware, so this page publishes no compatibility verdict for the family.

Request the Victron MultiPlus-II 48V checklist · WhatsApp +86 159 8945 0735
What the official document states
| Point | Published fact | What the installer confirms |
|---|---|---|
| Models | MultiPlus-II 48/3000/35-32, 48/5000/70-50, 48/8000/110-100, 48/10000/140-100 and 48/15000/200-100 | the rating plate on the unit on site |
| Battery type / charge defaults | not listed by type; factory charge defaults absorption 57.6 V, float 55.2 V, storage 52.8 V | the chemistry of the bank on site |
| Voltage range | 38–66 V; 66 V is confirmed per project | the pack’s planned charge-voltage limit against this window |
| Current | 35 / 70 / 110 / 140 / 200 A battery charge current for the 3 / 5 / 8 / 10 / 15 kVA models | the limit of this model and of the bank |
| Interface | VE.Bus port; monitoring and control via Cerbo GX or Ekrano GX | the intended method in the inverter documents |
| Other families | Deye, Sunsynk, SolaX and Growatt hybrids with a direct CAN/RS485 battery port, and Victron’s compatibility-list topic | do not copy figures from those families |
| Verdict | none is published here; a 51.2V name is not an approval | protocol and window confirmed per model and firmware |
A 51.2V name is not an approval. The official window of this family is 38–66 V; 66 V is confirmed per project. Figures from other families (Deye, Sunsynk, SolaX and Growatt hybrids with a direct CAN/RS485 battery port, and Victron’s compatibility-list topic) do not belong on this checklist.
What the installer sends before a proposal
- Inverter model and firmware version, read from the unit on site.
- Pack voltage, series count and BMS.
- The planned charge-voltage limit, checked against the 38–66 V window; 66 V is confirmed per project.
- Whether the cable is intended for CAN or for RS485.
- A written confirmation from the battery supplier, if available.
Treat this family as its own datasheet
Installers who record the window, the current limit of the exact model and the intended port on the first unit, instead of copying a row from another family, avoid a silent mismatch once several sites are wired. Prices and lead times only in a quotation for the Victron MultiPlus-II 48V.

Request a written check
Send the inverter model, the firmware, the pack series count and the intended port. We reply with the official window and the points still to be confirmed, not with a verdict.
LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.