Your tubular battery bank has done its job for a few years, and now the signs are familiar: the backup that used to run the fans and lights for four hours fades after two, the distilled-water top-ups come more often, and the inverter cuts off earlier every month. In a load-shedding home the tubular bank is a consumable — two to three years of daily cycling in hot weather, three to five with gentle use and careful watering — and the third replacement in a decade is when most buyers start asking what changes if they switch to lithium. This guide answers that question for the battery side of the swap: what a tubular battery actually delivers, what size of LiFePO4 battery replaces it, and the three checks that decide whether your existing inverter can charge it. A tubular battery’s amp-hour rating is measured at the C10 rate — drained over ten hours — so a 150 Ah battery delivers 150 Ah only at a gentle 15 A draw; drain it faster and you get less, because the acid cannot diffuse into the plates fast enough and the voltage sags to the inverter’s cut-off before the battery is truly empty. Only about half the rated energy is usable anyway, because discharging a tubular battery past 50% depth wears its plates out fast. A LiFePO4 battery gives back 80–90% of its rated energy at any household load, needs no water, no equalisation charging and no ventilated battery room, and is rated for thousands of cycles against a few hundred for a tubular battery. The swap is straightforward when the voltage matches and the charger is set right — and expensive when it is not, so the checks below come before the order, not after.
LJY Energy is a LiFePO4 battery supplier and OEM/ODM coordinator in Shenzhen; we are not a factory. This guide covers the battery side of replacing a tubular bank on an existing inverter only — which LiFePO4 battery matches your tubular bank, how to size it by usable energy, and what to check on the inverter before you order. The inverter itself, the wiring and the installation come from your installer or your existing unit. Two boundaries matter. First, do not change the system voltage and the battery chemistry in the same step: a 12 V inverter takes a 12.8 V pack, a 24 V inverter two 12 V units in series or one 25.6 V pack, a 48 V inverter four in series or one 51.2 V pack — and if you want a different voltage, replace the inverter as well. Second, this guide is about low-voltage home systems — 12 V, 24 V and 48 V — not about high-voltage or commercial battery strings. Start with the like-for-like replacement and add more in parallel as the load grows; the parallel limit for a bank is confirmed per project in the quotation, because it depends on the BMS configuration of the batteries you order.

Replacement reference
| Tubular sizes commonly replaced | 12 V · 150 Ah · 180 Ah · 200 Ah |
| Like-for-like LiFePO4 replacement | 12.8 V · 100 Ah · 1.28 kWh |
| Longer-backup LiFePO4 replacement | 12.8 V · 200 Ah · 2.56 kWh |
| Two-unit series replacement | 25.6 V · 100 Ah · 2.56 kWh |
| Four-unit series replacement | 51.2 V · 100 Ah · 5.12 kWh |
| Usable depth of discharge, LiFePO4 | 80–90% |
| Usable depth of discharge, tubular | 50% |
| Charge voltage, single-unit LiFePO4 | 14.2–14.6 V |
| Inverter compatibility | — |
Battery specifications live on the 12V 100Ah deep-cycle LiFePO4 battery page; confirm values on the product page and in the written quotation for your project.
Worked example
A 180 Ah tubular battery holds 2160 Wh on paper, but at 50% usable depth of discharge it returns about 1080 Wh — and less again at the speed a home inverter drains it. A 100 Ah LiFePO4 battery holds 1280 Wh and returns about 1024 Wh at 80% depth of discharge, so it matches or beats the tubular battery’s real backup with little more than half the amp-hour rating. Match the system voltage first: a 12 V inverter takes a 12.8 V pack, a 24 V inverter two in series or one 25.6 V pack, a 48 V inverter four in series or one 51.2 V pack. Turn equalisation off — it is a lead-acid charging stage a lithium pack must never receive — and confirm the inverter’s charge profile against the pack datasheet; compatibility is confirmed per project in the quotation.
What to send before a proposal
- Inverter make, model and DC voltage (12 V, 24 V or 48 V) — and whether it has a lithium or LiFePO4 charge profile, or manual voltage settings
- Existing tubular bank: how many batteries, the Ah rating on each, and the system voltage — plus the loads and backup hours you need
- Space and ventilation available for the new bank, and whether solar charging is part of the system
Request a sizing
Send the inverter model, the tubular bank details and the load list. LJY Energy will work out the replacement size and answer it in the quotation itself — which is where it belongs. Start with the like-for-like replacement and add more in parallel as the load grows; the expansion model is fixed from day one so a second battery in year two is a swap-in, not a redesign. Switch equalisation off, set the charge voltages from the pack datasheet, and confirm compatibility per project before the order — the checks take minutes and the wrong charger setting takes the battery. We coordinate OEM/ODM battery supply from Shenzhen; we are not a factory, and every order is confirmed in writing before production.

Request a tubular battery replacement quote · WhatsApp +86 159 8945 0735