LuxPower SNA battery brand codes: program 03 checklist

LuxPower SNA off-grid inverters are installed with 48V-class LiFePO4 batteries in homes and small businesses from Africa to Australia. In program 03 the installer chooses Li-ion and then a brand number such as 0 for Standard or 2 for Pylon. Anyone searching for LuxPower SNA battery brand settings wants to know what that number really selects and what the manual asks before it is set.

LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen, not a factory, and we make no claim about any LuxPower product. The public manual lists brand codes 0 Standard, 2 Pylon, 6 Luxpower and 8 Dyness, with 1 Hina added in the 2025 edition, and asks the installer to make sure the BMS is compatible by checking LuxPower’s list. Our protocol is stated in writing per firmware.

Front panel of a solar inverter with status display
Photo: Sunsathisolar, Wikimedia Commons, CC0 (resized, WebP). Illustration, not an LJY product.

Request a pairing check for a LuxPower inverter · WhatsApp +86 159 8945 0735

What the LuxPower manuals say

PointPublic sourceWhat to confirm per project
Program 03 typeLi-ion selected for a battery with BMSthat the battery communicates
Brand code0 Standard, 2 Pylon, 6 Luxpower, 8 Dyness, 1 Hina (2025)code given in writing by the battery supplier
BMS portCAN on pins 4/5, RS485 on pins 1/2cable pinout on both ends
Compatibilitymanual: make sure the BMS is compatible, check the listwritten pairing record
Firmwarecodes can change between manual editionsfirmware version on site

A brand code is a protocol choice, not an approval. Two batteries that both talk ‘Pylon’ can still differ in series count and charge window, so the datasheet is checked too.

Checklist before commissioning

  • Inverter model and firmware, and which manual edition matches it.
  • Battery model, BMS firmware and series count.
  • Brand code for program 03, given in writing by the battery supplier.
  • CAN or RS485 cable checked against pins 4/5 or 1/2.
  • BMS values on the inverter screen after the link comes up.

Note the firmware with the code

Installers who write down the inverter firmware next to the brand code avoid surprises when a later unit arrives with a newer manual edition. Prices and lead times only in a quotation.

Battery bank disconnect switches in a solar power room
Photo: A. E. Benoit, Wikimedia Commons, Public domain (resized, WebP). Illustration, not an LJY product.

How we proceed

Your LuxPower model and firmware → our protocol notes → bench or site test → documented pairing. We do not publish compatibility verdicts.

Send your LuxPower model and firmware and request a check

LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.