LiFePO4 battery for broiler house ventilation in South Africa

In Limpopo, North West, Mpumalanga, the Free State and KwaZulu-Natal, broiler and layer houses rely on tunnel fans and a house controller, and the load-shedding of 2022–2023 showed how quickly a house heats up when the grid drops before the generator is running and stable. Anyone searching for a LiFePO4 battery for broiler house ventilation in South Africa needs the bank in kWh from the measured watts of the controller, alarm and minimum ventilation × the bridging time, not from the sum of all fan nameplates.

LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory. We coordinate 25.6V and 51.2V banks. We do not supply fans, pads, controllers, generators or houses; the farm’s generator and alarm stay, and we make no claim about mortality, growth or uptime.

Young chickens in a broiler house, used to illustrate LiFePO4 batteries for ventilation in South Africa.
Photo: USDA NRCS Texas, Wikimedia Commons, Public domain (resized, WebP). Illustration, not an LJY product.

Request a poultry-house sizing · WhatsApp +86 159 8945 0735

Example: one tunnel-ventilated broiler house

LoadMeasured watts (example)Time on battery
Controller and alarmabout 150 W4 h
Minimum ventilation (3 fans)about 3.3 kW15 min
Totalabout 0.6 + 0.83 ≈ 1.4 kWhplus losses and a reserve

Example only. Measure the minimum ventilation the controller runs in an outage; the sum of fan nameplates is not the stored energy.

What the farm sends before a proposal

  • Measured controller and alarm watts.
  • Watts and number of fans for minimum ventilation.
  • Generator start time until the voltage is stable.
  • Battery location, enclosure and fusing, with dust and ammonia.
  • Number of houses for later repetition.

One house, then repeat

Farms and integrators that measure one house and repeat the bank across their houses simplify spares. Prices and lead times only in a quotation.

Polokwane, Limpopo, used to illustrate sizing a bank for poultry farms.
Photo: South African Tourism from South Africa, Wikimedia Commons, CC BY 2.0 (resized, WebP). Illustration, not an LJY product.

Request a poultry-house bank sizing

Send the measured loads and the generator start time. We reply with a kWh-based proposal for batteries only.

Send the house loads

LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.