LiFePO4 aerator batteries for fish farms in The Gambia

Around Banjul, Tanji, Gunjur and inland ponds, aerators have to keep running at night. A grid cut or a diesel set that is switched off can kill the stock before morning. Anyone searching for a LiFePO4 aerator battery for fish farms in The Gambia needs to turn the aerator’s measured input watts, and the night hours, into kWh — not copy the motor’s nameplate in kW. This page is about the bank that carries the aerator through the night. It is not a fishing-boat house-bank page, and we do not operate farms.

LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory, we do not install on the pond, and we do not run farms. We coordinate 12.8V, 25.6V and 51.2V banks. Charging is by a charger, a hybrid controller or a generator, as specified per farm. Enclosures must cope with heat, splash and salt spray; that detail is confirmed per project. We do not publish guaranteed survival claims for stock.

Banjul harbour, used as context for Gambia’s fishing and fish-farm coast
Photo: Maarten van der Bent, Wikimedia Commons, CC BY-SA 2.0 (resized, WebP). Illustration, not an LJY product.

Request a bank proposal for aerators on Gambia fish farms · WhatsApp +86 159 8945 0735

What the farm defines per pond

PointWhy it mattersConfirmed per project
12.8Vsmaller paddlewheels or blowersampere-hours and autonomy
25.6Vmedium pondskWh and how many units share the bank
51.2V wall-mountedlarger farms with a hybrid invertermodule count and inverter protocol
Night hoursthe real run, not the motor platehours recorded on that pond
Heat, splash and salt spraythe bank lives next to the waterenclosure and placement per project

The arithmetic is only a method: a 750 W input, measured at the aerator, for 10 hours asks for about 7.5 kWh, plus losses and a reserve. A night measured on that pond is worth more than a 1.5 kW motor plate.

What the farm sends before a proposal

  • Measured input watts of each aerator, not only the motor nameplate.
  • Typical night hours and how many units will share one bank.
  • System voltage already used on the farm, if any.
  • Heat, splash, salt spray and the space for the enclosure.
  • Whether a generator or a hybrid controller will recharge the bank.

Prove one pond, then repeat the bank

Farms that instrument a first pond, with real night hours, and then freeze the bank size, can extend the same design to neighbouring ponds without guessing. Prices and lead times only in a quotation.

Fishing boats in The Gambia, used as coastal context, not as a product image
Photo: Ikiwaner, Wikimedia Commons, CC BY-SA 3.0 (resized, WebP). Illustration, not an LJY product.

How we proceed

Measured input watts and hours → bank proposal → first pond → neighbouring ponds. Prices, quantities and lead times only in the formal offer.

Send the aerator load and night hours and request a proposal

LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.