Kampala’s boda-bodas are moving to electric motorcycles, and several operators run swap stations where a rider drops a flat pack and takes a full one. When motorcycles and cabinets come from different suppliers, a pack that seats in one station refuses the next, and heavy rain and potholes punish connectors. Anyone searching for a boda battery swap pack for a Kampala network needs one written specification, not a pack chosen by a 48V or 60V name (60V and 72V supply confirmed per project).
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen, not a factory, and we do not supply cabinets, motorcycles or chargers or run a network. We coordinate 51.2V 16S packs as the 48V-class reference. Any 60V or 72V pack is confirmed per project. The series count, charge cut-off, connector, mechanical size and BMS-to-cabinet protocol are written down before a pilot station opens in Kampala.

Request a swap-pack quote for a Kampala network · WhatsApp +86 159 8945 0735
What the operator locks in first
| Item | Why it matters | Confirmed per project |
|---|---|---|
| Series count | cabinets from two vendors may assume different series counts | cells in series, from the datasheet |
| Charge cut-off | each cabinet charger must stop where the BMS stops | charge voltage and current |
| Connector and size | the pack must enter every cabinet and every frame | drawing and lock |
| BMS-to-cabinet protocol | the station must recognise the pack | CAN or other link, in writing |
| Rain and shock | wet seasons and potholed roads | sealing, connector and cycle |
A voltage name is not a swap specification. Two operators that both say 48V or 60V can still use different series counts; 60V and 72V supply is confirmed per project.
Nominal voltage, charge cut-off, series count and BMS
A 48V, 60V or 72V nameplate (60V and 72V supply confirmed per project) does not say how many cells are in series or where a cabinet charger must stop. The table multiplies public per-cell values by the series count: LiFePO4 from the EVE LF304 datasheet, NMC from the Samsung SDI 18650-25R datasheet, and lead-acid from Battery University charge limits. Every 60V or 72V pack is confirmed per project.
| Chemistry and series | Nominal | Charge cut-off | BMS configuration |
|---|---|---|---|
| LiFePO4 16S (3.2V / 3.65V per cell) | 51.2V | 58.4V | 16S board |
| LiFePO4 20S | 64.0V | 73.0V | 20S board |
| LiFePO4 24S | 76.8V | 87.6V | 24S board |
| NMC 16S (3.6V / 4.2V per cell) | 57.6V | 67.2V | 16S board, NMC limits |
| NMC 20S | 72.0V | 84.0V | 20S board, NMC limits |
| Lead-acid 60V (5 × 12V, 30 cells, 2.30–2.45V per cell) | 60V | 69.0–73.5V | no BMS; LiFePO4 replacement confirmed per project |
| Lead-acid 72V (6 × 12V, 36 cells) | 72V | 82.8–88.2V | no BMS; LiFePO4 replacement confirmed per project |
A 60V lead-acid set charges up to about 73.5V, while a 20S LiFePO4 pack stops at 73.0V, so 60V supply is confirmed per project and each station charger is set to the pack, not the name. A 16S BMS cannot protect a 20S pack. We never infer compatibility from a voltage name.
What the operator sends before a quote
- Motorcycle models and the cabinet vendors already in the network.
- Connector, pack size and how the pack locks into the frame.
- Cabinet charger model and the protocol each vendor uses.
- Swaps per pack per day and the number of stations in the pilot.
- UN38.3 and SDS come with the quote; we do not run the network.
Pilot one station, then freeze the pack
Operators who run one pack family at a single Kampala station through a rainy season, then freeze the specification, avoid mixing connectors when stations open in Entebbe or Mukono. Prices and lead times only in a quotation.

How we proceed
Motorcycle, cabinet and protocol data → pack specification → station pilot → network orders. Prices and lead times only in the formal quote.
Send your motorcycle and cabinet data and request a specification
LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.