Victron publishes a battery compatibility page that names batteries known to have been tested with its products, mostly connected over BMS-Can to a GX device. Installers are often offered a battery that is not on that list. Anyone searching for a battery not on Victron’s compatibility list wants to know whether it can still be used, what Victron itself says, and what to confirm before the purchase.
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen, not a factory. Our batteries are not on Victron’s tested list, and we do not claim they are. Victron’s page states that other third-party batteries may be used under warranty with support from a local supplier, and that Victron shares its battery protocol specification with battery makers on request. Any pairing with a Victron system is confirmed per project.

Request a test unit review for a Victron system · WhatsApp +86 159 8945 0735
What Victron’s page says, and what to confirm
| Point from Victron’s page | Why it matters | Buyer checklist |
|---|---|---|
| Tested list of named batteries | Victron-tested combinations | is the exact battery model listed? if not, who supports it |
| Other batteries permitted with local supplier support | warranty and support path | named local support contact in writing |
| BMS should lower the charge voltage limit (CVL) near full | limiting only current can cause alarms | confirm CVL behaviour in the BMS documentation and on test |
| Battery must have its own disconnect, such as a contactor | digital signals alone are not enough | confirm the disconnect device in the battery datasheet |
| LJY inverter communication guide | documented settings | reference only, not a verdict |
Victron also describes problems seen with DIY BMS units that set charge current to zero when full: overload or overcharge warnings that disappear on the test bench. These points are checked on a test before a project is rolled out.
What to send before ordering
- GX device model and firmware version.
- Inverter/charger model (for example a Quattro or MultiPlus) and firmware.
- Battery BMS protocol and the documentation of its CVL and CCL behaviour.
- Battery disconnect design and rating.
- Who provides local support for the battery.
Test first, then repeat
Installers who bench-test one battery with their GX setup, record the settings and only then roll it out avoid alarm troubleshooting on site. Prices and lead times only in a quotation.

How we proceed
Victron system data and firmware → BMS documentation review → test unit → project decision. No compatibility verdict is published in advance.
Send your Victron system details and request a review