When the power goes out at night, a CPAP machine and a home oxygen concentrator fail in very different ways — and they need very different batteries. A CPAP is a small blower: without its heated humidifier it typically draws about 10–30 W, so a single night of sleep takes roughly 120–240 Wh, and a small 12 V pack covers it. Switch the heated humidifier and heated tube on and the same machine draws about 30–70 W, roughly doubling the night’s energy. A stationary oxygen concentrator is a different job entirely: a 5-litre home unit typically draws about 250–350 W around the clock, a 10-litre unit about 500–600 W, so one day of oxygen takes several kilowatt-hours — whole-home storage, not a bedside pack. This guide is about sizing the battery for each case: the watt ranges that decide the size, the runtime formula that turns watts into nights and hours, and how to start with one pack and add modules as the need grows. Every watt figure here is a planning range, not a specification for your machine — check the nameplate on your own device and in its manual before you size anything, because the same kind of machine can draw twice as much at a high setting as at a low one. This page is an equipment sizing guide, not medical advice: it does not promise that any battery will keep a treatment running, and any outage plan for a prescribed device should be agreed with the clinician who prescribed it and the company that supplied the equipment.
LJY Energy is a LiFePO4 battery supplier and OEM/ODM coordinator in Shenzhen; we are not a factory, and we do not make or sell medical devices. This guide covers the battery side of home medical backup only — which pack size matches a CPAP or a home oxygen concentrator, how to work out the runtime, and how the pack grows with the need. It is an educational equipment guide, not medical advice: it does not promise that any battery will keep a treatment running, it does not replace the instructions of the clinician who prescribed the device or the company that supplied it, and a battery is never a substitute for the emergency plan those professionals agree with you. Two boundaries matter. First, this guide is about low-voltage home systems — 12 V, 24 V and 48 V packs — not about higher-voltage or commercial battery strings, and not about the inverter, the wiring or the installation, which come from your installer. Second, the numbers here are planning ranges: the watt figure that sizes your pack is the one on your own device’s nameplate, and the pack size itself is confirmed per project in the quotation. Start with one pack and add modules in parallel as the need grows; the parallel limit for a bank is confirmed per project in the quotation, because it depends on the BMS configuration of the batteries you order.

Sizing reference
| CPAP draw, no humidifier | 10–30 W |
| CPAP draw, heated humidifier on | 30–70 W |
| Stationary concentrator draw, five-litre | 250–350 W |
| Stationary concentrator draw, ten-litre | 500–600 W |
| Portable concentrator draw | 60–130 W |
| One-night CPAP energy, no humidifier | 120–240 Wh |
| One-night CPAP energy, humidifier on | 240–520 Wh |
| Reference pack energy | 12.8 V · 100 Ah · 1.28 kWh |
| Longer backup | — |
Battery specifications live on the 12V 100Ah deep-cycle LiFePO4 battery page; confirm values on the product page and in the written quotation for your project.
Worked example
A CPAP drawing 20 W for an 8-hour night needs 160 Wh before conversion losses. A 256 Wh pack delivers about 85% of that through a DC cord, so it covers roughly 10 hours — about one night with the humidifier off. A stationary concentrator drawing 350 W is a different job: a 5.12 kWh module holds about 4.1 kWh usable at 80% depth of discharge, which runs it for roughly 12 hours. Size from your own nameplate watts, not from these examples, and confirm the pack size per project in the quotation.
What to send before a proposal
- Device nameplate watts and the hours of backup you need — CPAP with or without the heated humidifier, concentrator flow setting and litres per minute
- Whether the device runs on its own DC cord or needs an inverter, and the inverter model if one is already installed
- How many nights or days the backup must cover, and whether solar charging is part of the system
Request a sizing
Send the device nameplate watts, the hours you need covered and whether the humidifier stays on. LJY Energy will work out the pack size and answer it in the quotation itself — which is where it belongs. Start with one pack and add modules in parallel as the need grows; the expansion model is fixed from day one so a second pack next year is a swap-in, not a redesign. Size from your own nameplate, not from the ranges on this page, and agree any outage plan for a prescribed device with your clinician and equipment provider — this guide is equipment information, not medical advice. We coordinate OEM/ODM battery supply from Shenzhen; we are not a factory, and every order is confirmed in writing before production.

Request a home medical backup quote · WhatsApp +86 159 8945 0735