The Quattro 48/5000/70-100/100, 48/8000/110-100/100, 48/10000/140-100/100 and 48/15000/200-100/100 units form one 48 V inverter/charger family with two AC inputs. Anyone searching for a Victron Quattro 48V battery checklist needs the official battery-voltage window, the current limit by model and the ports, not a compatibility verdict inferred from a 51.2V name or copied from another family. The official range is 38–60 V; 60 V is confirmed per project. The Quattro is not a MultiPlus-II: its 48 V window ends at 60 V, not 66 V, and it has two AC inputs for a generator and a grid or shore supply. A pack set up for one family is not automatically set up for the other.
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory and we do not sell this inverter. We coordinate 51.2V modules; in a Victron system the battery link is confirmed per GX device and battery documentation. The charge settings, the charge window and the intended port are confirmed per inverter model and firmware, so this page publishes no compatibility verdict for the family.

Request the Victron Quattro 48V checklist · WhatsApp +86 159 8945 0735
What the official document states
| Point | Published fact | What the installer confirms |
|---|---|---|
| Models | Quattro 48/5000/70-100/100, 48/8000/110-100/100, 48/10000/140-100/100 and 48/15000/200-100/100 | the rating plate on the unit on site |
| Battery type / datasheet charge values | the datasheet headline says ‘Lithium Ion battery compatible’ (a general statement, not an approval of a battery); datasheet charge values absorption 57.6 V, float 55.2 V, storage 52.8 V | the chemistry of the bank on site |
| Voltage range | 38–60 V; 60 V is confirmed per project | the pack’s planned charge-voltage limit against this window |
| Current | 70 / 110 / 140 / 200 A house-battery charge current for the 5 / 8 / 10 / 15 kVA models | the limit of this model and of the bank |
| Interface | VE.Bus port; two AC inputs (187–250 VAC) with an integrated transfer switch | the intended method in the inverter documents |
| Other families | the MultiPlus-II 48V (38–66 V) and Deye, Sunsynk, SolaX or Growatt hybrids with a direct CAN/RS485 battery port | do not copy figures from those families |
| Verdict | none is published here; a 51.2V name is not an approval | protocol and window confirmed per model and firmware |
A 51.2V name is not an approval. The official window of this family is 38–60 V; 60 V is confirmed per project. Figures from other families (the MultiPlus-II 48V (38–66 V) and Deye, Sunsynk, SolaX or Growatt hybrids with a direct CAN/RS485 battery port) do not belong on this checklist.
What the installer sends before a proposal
- Inverter model and firmware version, read from the unit on site.
- Pack voltage, series count and BMS.
- The planned charge-voltage limit, checked against the 38–60 V window; 60 V is confirmed per project.
- Which GX device and battery documents will carry the battery link.
- A written confirmation from the battery supplier, if available.
Treat this family as its own datasheet
Installers who record the window, the current limit of the exact model and the intended port on the first unit, instead of copying a row from another family, avoid a silent mismatch once several sites are wired. Prices and lead times only in a quotation for the Victron Quattro 48V.

Request a written check
Send the inverter model, the firmware, the pack series count and the intended port. We reply with the official window and the points still to be confirmed, not with a verdict.
LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.