In Accra, Kumasi and Tamale, small sachet-water producers run a borehole or feed pump, a reverse-osmosis pump, a UV unit and a filling and sealing machine, and dumsor outages stop the line or force a genset to run for every short cut. Anyone searching for a LiFePO4 battery for sachet water RO plants in Ghana needs the bank sized in kWh from measured watts × the hours the station must keep producing or selling on battery, not from a pump’s nameplate kW or a copied ampere-hour label. Product registration and water quality stay with the producer; this page is only about the battery.
LJY Energy is a LiFePO4 supplier and OEM/ODM coordinator in Shenzhen; we are not a factory. We coordinate 25.6V and 51.2V banks for the electrical load of a water station. We do not supply RO units, membranes, UV units, dispensers, filling machines or tanks, and we make no claim about water quality or litres per day; those belong to the equipment maker and the local authority.

Request a water-station battery sizing · WhatsApp +86 159 8945 0735
Example: one small station
| Load | Measured watts (example) | Hours on battery |
|---|---|---|
| Feed / borehole pump | about 750 W | 3 h |
| RO high-pressure pump | about 1.1 kW | 3 h |
| UV unit | about 40 W | 3 h |
| Filling and sealing machine | about 2 kW | 3 h |
| Total | about 3.89 kW × 3 h ≈ 11.7 kWh | plus losses and a reserve |
The figures are an example only. Measure your own equipment and the hours the station must run on battery; pump start current is confirmed with the inverter.
What the operator sends before a proposal
- Measured watts of each pump, the UV unit and the dispenser or filling machine.
- Hours per day on battery and the typical outage pattern.
- System voltage (230 V 50 Hz) and the inverter model, including pump start current.
- Whether a PV array or a genset is already on site.
- Where the bank sits and the temperature there in the hot season.
Measure one station, then repeat the design
Operators with several Ghanaian outlets who measure one station and repeat the same bank spend less time on spares and training. Prices and lead times only in a quotation.

Request a station battery sizing
Send the measured loads, the hours on battery and the inverter model. We reply with a kWh-based bank proposal for batteries only.
LJY Energy, Jack Lai. Unit 705, Building 1, Lecai Industrial Park, 10 Kaijing Road, Longtian Street, Pingshan District, Shenzhen 518122, China. +86 159 8945 0735.
