Scissor Lift & Aerial Work Platform Battery — 24V / 48V LiFePO4 Conversion

Product Overview

A LiFePO4 battery built to replace the lead-acid pack in electric scissor lifts and other aerial work platforms. Most slab scissor lifts run a 24V system — typically four 6V flooded batteries wired in series — and this pack takes their place as a single unit with one built-in BMS managing every cell: no series interconnects, no watering, no equalization charges. For larger scissor lifts, vertical mast lifts and boom lifts on 48V-class systems, the same conversion is built at 51.2V.

The buyers are rental fleets, equipment dealers and service workshops running conversion programs across mixed fleets. As a China-based LiFePO4 battery supplier and OEM/ODM coordination partner, LJY Energy configures each pack against the machine it will power. Fitment is confirmed in writing per equipment brand and model before any order — we do not publish blanket compatibility claims.

Why Rental Fleets and Owners Convert to Lithium

Flooded lead-acid is a poor match for rental duty. Renters run packs deep, machines sit between hires, watering gets skipped, and a charger left connected applies equalization cycles the pack did not need. The result is sulfation and a battery that becomes a recurring workshop cost — labour to swap, a machine out of service, and a hire turned away while it waits.

A LiFePO4 conversion removes most of those failure modes:

  • No maintenance labour. No watering, no terminal corrosion routine, no equalization stage.
  • Opportunity charging without the penalty. Lithium tolerates partial charging between hires; topping up a lead-acid pack short of full, repeatedly, is exactly what shortens its life.
  • More usable energy per nameplate amp-hour. At a sensible 80% depth of discharge, a 105Ah lithium pack returns about 84Ah of working capacity, against roughly half the nameplate from a lead-acid set kept above 50%.
  • Consistent performance through the shift. The flat discharge curve holds drive and lift performance instead of the steady sag operators feel as a lead-acid pack empties.
  • Long service life. Around 6,000 cycles at 80% depth of discharge is the typical cell-level reference for quality LiFePO4 cells; pack life depends on BMS, thermal design and duty, and warranty is confirmed per configuration and order agreement.

One honest caveat, and it matters: a lithium pack weighs roughly half as much as the lead-acid set it replaces. On machines where that battery mass forms part of the counterweight, the conversion changes the machine’s balance and has to be engineered, not just dropped in. That is what the fitment checklist below is for.

Typical Configurations

Values below are typical configurations. “To be confirmed” items depend on the machine model and the final build — contact us for the datasheet of the exact configuration you need.

Group Parameter Value Status
Electrical Battery chemistry LiFePO4 (lithium iron phosphate) Typical
Electrical Nominal voltage 25.6V (8S) / 51.2V (16S) Typical
Electrical Typical capacities — 24V 105Ah / 135Ah / 168Ah (2.7–4.3kWh) Typical
Electrical Typical capacities — 48V class 105Ah / 280Ah at 51.2V (5.4–14.3kWh) Typical
Electrical Charge voltage (bulk/absorption) 28.4–29.2V (24V) / 56.8–58.4V (51.2V) Typical
BMS Protection Over-charge / over-discharge / over-current / short-circuit / temperature protection Typical
BMS Continuous discharge rating Sized to the machine’s drive and lift load To be confirmed per machine model
BMS Monitoring & communication SOC indication; Bluetooth or CAN/RS485 where the machine requires it Optional — subject to configuration
Mechanical Weight Approx. 50% lighter than the lead-acid set replaced — see counterweight check Typical
Mechanical Dimensions & compartment fit Matched to the machine’s battery compartment and tray To be confirmed per machine model
Mechanical Counterweight compensation Ballast or counterweight solution where the original pack contributes to machine counterweight To be confirmed per machine model
Charging Charger LiFePO4-profile charger matched to pack voltage; the original lead-acid charger is not assumed compatible To be confirmed per configuration
Documents Transport & safety files UN38.3 test summary; SDS confirmed per model To be confirmed per model
Commercial Warranty terms Subject to configuration and order agreement To be confirmed
Commercial Lead time Subject to order quantity and configuration To be confirmed

Conversion & Fitment Checklist

Before quoting a conversion, we work through the machine, not just the battery:

  1. The outgoing pack. System voltage, nameplate capacity, chemistry (flooded or AGM), how many blocks and how they are wired. A photo of the battery label answers most of this.
  2. The compartment. Internal length × width × height, tray and hold-down arrangement, cable entry, terminal positions and the connector type and polarity the machine expects.
  3. Weight and balance. Weigh the outgoing lead-acid set. If it contributes to the machine’s counterweight, the lighter lithium pack needs a ballast or counterweight assessment for that model, and machine stability remains governed by the equipment manufacturer’s specifications. This is the step quick “drop-in” conversions skip.
  4. The charger. Flooded charge profiles — including the equalization stage — are not suitable for lithium. Plan on a matched LiFePO4 charger, or a verified reprofile of existing fleet chargers where the hardware allows it.
  5. The electrical load. Drive and lift motor peak draw against the BMS continuous and peak ratings, and the machine controller’s own low-voltage behaviour, which was often set around a lead-acid discharge curve.
  6. The duty. Shifts per day, opportunity charging between hires, indoor or outdoor storage, and cold yards — below-freezing charging needs low-temperature protection or a heating option, specified per build.

Fitment for each machine model is confirmed in writing against this checklist before production.

Wholesale, OEM & Fleet Programs

  • Wholesale: supply for equipment dealers, rental groups and service networks; terms vary by configuration and order size.
  • Fleet conversion programs: one confirmed specification per machine model, documented on a per-model fitment sheet, so repeat orders rebuild the same pack for the same machine.
  • OEM branding: enclosure, logo, labeling and packaging for your brand.
  • Trial conversions: start with one machine, run it in your own fleet, then roll the confirmed specification across the model line.
  • Documentation support: UN38.3 test summary and per-model SDS coordinated per order.

Frequently Asked Questions

Can I drop a lithium pack straight into my scissor lift?

Electrically, a 24V LiFePO4 pack matches a 24V machine. But “drop-in” skips three checks that decide whether the conversion is sound: compartment fit, charger profile, and weight — many scissor lifts use the battery’s mass as part of the counterweight. Send us the machine brand and model and we confirm fitment in writing before you commit.

Which lithium size replaces my 24V lead-acid set?

Typical conversions are 105Ah, 135Ah or 168Ah at 25.6V. The lithium rating does not need to match the lead-acid nameplate one-for-one: lithium works at around 80% depth of discharge against roughly 50% for lead-acid, so a smaller lithium pack often covers the same shift. The right size comes from the machine’s duty, which we check with you per model.

Will my existing charger work?

Usually not as it stands. Flooded lead-acid profiles include voltage curves and an equalization stage that lithium should not see. Budget for a matched LiFePO4-profile charger, or ask us to check whether your fleet chargers can be reprofiled — confirmed per configuration.

How long does the pack last in rental service?

The typical cell-level reference for quality LiFePO4 cells is around 6,000 cycles at 80% depth of discharge; real pack life depends on duty, BMS and thermal conditions. The rental-relevant point is what lithium removes: no watering to skip, no sulfation from partial charging between hires — the two things that kill most flooded packs early. Warranty terms are confirmed per configuration and order agreement.

Does the lighter weight affect machine stability?

It can, which is why weight is a checklist item and not a footnote. Where the original pack forms part of the machine’s counterweight, the conversion needs a ballast or counterweight solution assessed for that model, and the machine’s stability remains governed by the equipment manufacturer’s specifications. Our written fitment confirmation covers the battery side of that assessment for your model.

Can you supply conversions for a mixed fleet?

Yes. Each machine model gets its own confirmed specification and fitment sheet — a 24V slab scissor specification does not transfer to a 48V machine. Most fleet customers trial one machine first, then roll the confirmed specification across that model line.

Request a Conversion Specification

Send the machine brand and model, the original battery specification or a photo of its label, the fleet size you are converting, and your destination port. We reply with the configuration and the written fitment confirmation for that model: request an AWP conversion specification.

Specifications are typical configurations and subject to the final order specification. Fitment, documentation, warranty, dimensions, lead time and pricing are confirmed per inquiry. Content as of November 2026.