# OEM/ODM LiFePO4 Battery Specification Request (RFQ) Template LJY Energy · ljyenergy.com · version 2026-10-28 You don't need to fill every line to start. Mark each line **Required**, **Preferred** or **Open (advise me)**. A supplier that confirms each line in writing, and flags what it cannot confirm, saves you a re-quote, a failed sample or a disputed shipment. Keep the confirmed version: it is the reference for samples, mass production, inspection and warranty claims. LJY Energy is a supplier and OEM/ODM coordinator, not a factory. MOQ, price, lead time, warranty and capacity are confirmed per project in the quotation. Certificates are available or arranged per project; testing and certification fees are borne by the buyer. Project / company: ____________________ Contact: ____________________ Date: __________ ## A. Project and application | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | A1 | **Company type and role**: OEM equipment maker / brand owner / distributor / integrator / installer | | | | | | A2 | **Application and duty cycle**: e.g. golf cart, RV house bank, marine trolling, telecom backup, home ESS, AGV; hours per day, cycles per day, float vs cycling | | | | | | A3 | **Equipment the battery must work with**: inverter/charger/controller/motor brand and **exact model**, firmware if known | | | | | | A4 | **Operating environment**: indoor/outdoor, vibration (vehicle/boat), altitude, humidity/salt spray | | | | | | A5 | **Target markets (countries)**: list every country of sale | | | | | ## B. Electrical | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | B1 | **Nominal voltage**: 12.8 / 25.6 / 38.4 / 51.2 V or other; series count if known | | | | | | B2 | **Capacity / energy**: Ah **and** Wh/kWh; usable vs nominal | | | | | | B3 | **Operating voltage window**: min/max V at the equipment terminals | | | | | | B4 | **Continuous discharge current**: A, at what ambient temperature | | | | | | B5 | **Peak / surge current**: A and duration (e.g. 2× for 10 s, motor inrush, inverter start) | | | | | | B6 | **Charge current and charger**: max charge A, charger type (alternator, DC-DC, solar MPPT, inverter-charger) | | | | | | B7 | **Capacity test basis**: discharge rate (e.g. 0.2C/0.5C), temperature, cut-off voltage, charge method | | | | | | B8 | **Cycle-life claim basis (if requested)**: cycles to what end-of-life % at what DoD, C-rate and temperature | | | | | | B9 | **Series/parallel expansion**: max units in parallel/series, and whether the BMS supports it | | | | | | B10 | **Self-discharge / storage**: expected storage time before use, storage SoC | | | | | ## C. Cells | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | C1 | **Cell chemistry**: LiFePO4 (LFP) | | | | | | C2 | **Cell format**: prismatic / cylindrical (e.g. 32700) / pouch; preferred capacity (e.g. 100/105/280/314Ah) | | | | | | C3 | **Cell brand/model preference**: named brand and model, or "supplier to propose, in writing" | | | | | | C4 | **Cell grade and new/unused requirement**: new, unused, same production batch; matching criteria (capacity, IR, voltage spread) | | | | | | C5 | **Cell traceability**: QR/serial readable and recorded per pack; batch test report | | | | | | C6 | **Cell test evidence**: cell maker datasheet; cell UN38.3; cell IEC 62619 / UL 1642 if applicable | | | | | ## D. BMS and communication | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | D1 | **BMS rating**: continuous/peak A, MOSFET or relay/contactor | | | | | | D2 | **Protection set-points**: over-/under-voltage per cell, over-current, short-circuit, over-temperature, low-temperature charge cut-off | | | | | | D3 | **Balancing**: passive/active, balance current | | | | | | D4 | **Communication protocol**: CAN / RS485 / RS232 / Bluetooth / none; protocol name (e.g. "Pylontech-compatible CAN"), baud rate, ID setting | | | | | | D5 | **Equipment pairing evidence**: wanted: test log or screenshot with your exact inverter/controller model and firmware | | | | | | D6 | **Monitoring / app**: Bluetooth app, display/SOC meter, data export | | | | | | D7 | **Firmware**: who holds it, update method, change notification | | | | | | D8 | **Wake-up / shutdown behaviour**: sleep mode, wake by charge or button, standby drain | | | | | ## E. Temperature | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | E1 | **Operating range**: charge °C range, discharge °C range | | | | | | E2 | **Self-heating**: required / not required; heating power and trigger temperature; heating energy source | | | | | | E3 | **High-temperature derating**: max ambient, enclosure ventilation | | | | | ## F. Mechanical, enclosure and terminals | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | F1 | **Max dimensions L×W×H and weight**: mm/kg; group size (e.g. BCI 24/27/31, 8D, GC2) if replacing lead-acid | | | | | | F2 | **Enclosure material**: ABS/PC, steel, aluminium; colour | | | | | | F3 | **Ingress protection**: IP rating needed (e.g. IP65/IP67) | | | | | | F4 | **Mounting and orientation**: upright only / any orientation; rack 19-inch; wall mount; fixing points | | | | | | F5 | **Vibration / shock requirement**: vehicle or marine; standard or test you require | | | | | | F6 | **Terminals**: stud size (M6/M8/M10), terminal type, polarity layout, torque spec | | | | | | F7 | **Breaker / switch / fuse**: built-in breaker, on/off switch, fuse requirement | | | | | | F8 | **Handles, cable kit, accessories**: handles, cables, comms cables, brackets | | | | | ## G. Branding, labelling and documentation | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | G1 | **Private label scope**: logo on case, rating label, model naming, colour | | | | | | G2 | **Label content by market**: rating label fields, warnings, symbols, languages, serial/date code, QR | | | | | | G3 | **Manual and documents**: user manual, installation guide, spec sheet, in which languages | | | | | | G4 | **Model-number control**: your model name ↔ supplier model, written mapping | | | | | ## H. Packaging and shipping | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | H1 | **Shipping classification**: UN3480 (batteries alone) / UN3481 (packed with or contained in equipment) | | | | | | H2 | **Transport mode**: sea (IMDG) / air (IATA DGR) / road / rail; FCL or LCL | | | | | | H3 | **Shipping documents required**: UN38.3 test summary (pack-level, your model), SDS, DG declaration, packing certificate if required by carrier | | | | | | H4 | **Packaging spec**: carton/wood case, drop/stack requirement, pallet type, units per carton/pallet, SoC at shipment | | | | | | H5 | **Incoterm and ports**: EXW/FOB/CIF/DAP/DDP **+ Incoterms 2020**, origin/destination port | | | | | ## I. Certifications and compliance (by market) _List what your market requires. The supplier answers per model and project: available or arranged per project, with testing and certification fees borne by the buyer._ | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | I1 | **Required standards by market**: examples, check with your compliance advisor: UN38.3 (transport, all markets); IEC 62619 (industrial/ESS); IEC 62133-2 (portable); UL 1973 (stationary/auxiliary incl. RV); UL 9540/9540A (ESS systems, US); UL 2271 (light EV incl. golf/LSV); CE + EU Battery Regulation 2023/1542 (EU); market listings such as Australia CEC | | | | | | I2 | **Who holds each certificate**: named holder on each certificate/report (cell maker, pack maker, brand) | | | | | | I3 | **Witness or own testing**: will you test samples at your own lab or a third party? | | | | | | I4 | **Budget and timeline owner**: who pays and when; re-test if the design changes | | | | | ## J. Quantities, forecast and commercial | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | J1 | **Sample quantity**: e.g. 2–5 units per configuration | | | | | | J2 | **Trial / pilot order**: quantity band | | | | | | J3 | **Annual forecast**: quantity band per year, seasonality, number of SKUs | | | | | | J4 | **Quantity tiers for pricing**: e.g. 50 / 200 / 1000 units | | | | | | J5 | **Payment preference**: T/T split, L/C, other | | | | | | J6 | **Target price or budget band (optional)**: band per unit or per kWh | | | | | ## K. Samples, QC and inspection | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | K1 | **Sample acceptance tests**: capacity at stated conditions, IR, cell voltage spread, BMS protection check, comms pairing with your equipment, fit check | | | | | | K2 | **Golden sample**: sealed reference unit kept by both sides | | | | | | K3 | **Production QC records**: per-pack test record (OCV, IR, capacity or charge/discharge check, insulation, BMS function), serial list | | | | | | K4 | **Third-party inspection**: pre-shipment inspection by an agency you appoint (e.g. SGS, BV, TÜV, Intertek, QIMA); sampling plan (e.g. ISO 2859-1 Level II); AQL for critical/major/minor | | | | | | K5 | **Change control**: supplier must notify before changing cell, BMS, firmware or enclosure | | | | | ## L. Warranty terms to negotiate (not fixed numbers) | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | L1 | **Warranty basis**: years / cycles / throughput (MWh) / end-of-life capacity %, whichever comes first | | | | | | L2 | **Who issues and who receives claims**: issuing party, contact, language | | | | | | L3 | **Exclusions**: misuse, wrong charger settings, storage, physical damage | | | | | | L4 | **Remedy options**: repair / replace / credit; advance replacement or not | | | | | | L5 | **DOA window**: days after arrival and the test method | | | | | ## M. After-sales and RMA | # | Field (what to write) | Your requirement | Required / Preferred / Open | Supplier confirmation | Evidence supplied (doc name, rev.) | |---|---|---|---|---|---| | M1 | **First-line diagnosis**: what the distributor/installer checks before raising a claim | | | | | | M2 | **Claim evidence**: serial, date code, photos, voltages, BMS screenshot/log, install details | | | | | | M3 | **Response and decision time**: target time for first reply and for decision | | | | | | M4 | **Spare units / parts**: spare share with the order, BMS boards, cables | | | | | | M5 | **Returns logistics**: whether the unit must return; who arranges DG return and pays | | | | | --- Why each line matters: see the on-page checklist at https://ljyenergy.com/oem-odm/#oem-rfq-checklist Send the filled template: https://ljyenergy.com/contact/?product=OEM-ODM · jack@ljyenergy.com · WhatsApp +86 159 8945 0735 (https://wa.me/8615989450735)